MODEL | GASTYPE | INPUT BTU/HR | IGNITION | MINIMUM MOUNTING HEIGHT(feet) |
RSCA3-N5 | Natural | 26,000 | DirectSpark Ignition | 10 |
RSCA6-N5 | Natural | 52,000 | Direct Spark Ignition | 12 |
RSCA10-N5 | Natural | 104,000 | Direct Spark Ignition | 14 |
RSCA3-L5 | Propane | 26,000 | DirectSpark Ignition | 10 |
RSCA6-L5 | Propane | 52,000 | Direct Spark Ignition | 12 |
RSCA10-L5 | Propane | 104,000 | Direct Spark Ignition | 14 |
RSCA3-N1 | Natural | 26,000 | MillivoltStanding Pilot | 10 |
RSCA6-N1 | Natural | 52,000 | Millivolt Standing Pilot | 12 |
RSCA3-L1 | Propane | 26,000 | MillivoltStanding Pilot | 10 |
RSCA6-L1 | Propane | 52,000 | Millivolt Standing Pilot | 12 |
Floor Level Coverage – The above chart may be used as a guideline for primary radiation, i.e. the infrared pattern directly below the heater. In a well-insulated building, only 50% of the floor needs to be covered by the primary radiant pattern. Please be aware that the radiant energy generated by infrared heaters is not limited to the primary radiant pattern. There is additional radiant energy that is absorbed outside the primary area, a secondary radiant pattern. Since concrete is a very good conductor of heat, a reasonably uniform floor temperature eventually will be reached. The amount of time it takes to reach “thermal equilibrium” is in direct correlation to the distance between the heaters.
Learn More >>
BURNER AND BODY CONSTRUCTION
- Durable Cast Iron Burner For Precision-Crafted Performance And For Proper Combustion
- 10-Year Limited Warranty On Cast Iron Burner
- Stainless Steel Tile Retainer Assembly
- Corrosion Resistant Aluminized Steel Body Construction
- 10-Year Limited Warranty On Body
- Specially Designed Internal Plenum Chamber For Proper Air/Gas Mixture
EMITTER SURFACE
- Coated High Temperature Emitter Tiles For Higher Radiant Efficiency
- Up to 1800°F Surface Temperature
- Iron Oxide Coating Increases Surface Emissivity By 13%
- 10-Year Limited Warranty On Emitter Tiles
- Incoloy 800 Reverberatory Screen For Secondary Radiating Surface And Additional Safety
REFLECTOR
- Highly efficient Aluminum Reflectors
- Double Formed Edges For Rigidity
- Optional Parabolic Extension For Higher Mounting Heights
OTHER
- Simple Chain Mounting
- Rigid Mounting and Heavy Duty Wall Mounting Bracket Kits are available as accessories
- ½” NPT Female Gas Pipe Connection
- Heaters can be shipped by UPS
- CSA Certified according to ANSI Z83.19 and CSA 2.34. NOT Certified for Residential Use
MODEL | GAS TYPE | INPUT BTU/HR | NO. OF BURNERS | DIMENSIONS(inches) | SHIPPING WEIGHT (lbs.) | ||
LENGTH | WIDTH | HEIGHT | |||||
RSCA3 | Natural | 26,000 | 1 | 19 15/16 | 16 3/4 | 9 3/4 | 30 |
RSCA6 | Natural | 52,000 | 1 | 30 7/8 | 16 3/4 | 9 3/4 | 40 |
RSCA10 | Natural | 104,000 | 1 | 52 | 16 3/4 | 9 3/4 | 70 |
N5 or L5 DIRECT SPARK IGNITION MODELS
GAS TYPE | BURNER PRESSURE | MINIMUM SUPPLY PRESSURE | MAXIMUM SUPPLY PRESSURE | VOLTAGE | AMPS | IGNITION TYPE |
NATURAL | 6″ W.C. | 7″ W.C. | 14″ W.C. | 120 VAC 60HZ | 0.4 | DIRECT SPARK |
PROPANE | 10″ W.C. | 11″ W.C. | 14″ W.C. |
N1 or L1 MILLIVOLT CONTROL (STANDING PILOT) MODELS
GAS TYPE | BURNER PRESSURE | MINIMUM SUPPLY PRESSURE | MAXIMUM SUPPLY PRESSURE | VOLTAGE | AMPS | IGNITION TYPE |
NATURAL | 6″ W.C.* | 7″ W.C. | 14″ W.C. | MILLIVOLT** | ** | MILLIVOLT STANDING PILOT |
PROPANE | 10″ W.C. | 11″ W.C. | 14″ W.C. |
* 3.5″ for RSCA3-N1
** Note: MILLIVOLT CONTROL (STANDING PILOT) MODELS require Millivolt Thermostat -Part# 42489010
Model No. | Sides | Ceiling | Below | Below (45°) | Front (45°) | Rear (45°) | Angle Mtg. (degree) | ||
Standard Reflector | w/Parabolic Extension | Standard Reflector | w/Parabolic Extension | ||||||
RSCA3 | 24 | 24 | 48 | 48 | 126 | 48 | 50″ | 8 | 0 min 45 max |
RSCA6 | 30 | 36 | 72 | 72 | 126 | 72 | 68″ | 12 | 0 min 45 max |
RSCA10 | 48″ | 36 | 96 | 96 | 168 | 96 | 84″ | 18 | 0 min 45 max |
NOTE:The clearances specified above must be maintained to combustibles and other materials that may be damaged by temperatures 90°F above ambient temperature. Clearances to combustibles are posted on the reflector near the control end of the heater. In locations used for storage of combustible materials where they may be stacked below the heater, NFPA 54 requires that the installer must post signs that will “specify the maximum permissible stacking height to maintain the required clearances from the heater to combustibles”.
WARNING: NOT FOR RESIDENTIAL USE.
This heater is not approved for any residential installation including home, residential garage or recreational use (mobile home, RVs, Campers etc.). and require ventilation per National Codes. See the I&Os for complete installation requirements. For residential garage applications, Space-Ray recommends Cold Blocker (CB Series) vented tube heaters.
VENTING REQUIREMENTS
This is an indirect vented heater and requires a minimum ventilation flow of 4 CFM per 1000 BTU/hour of total installed heater capacity on natural gas by either gravity or power ventilation (4.18 CFM per 1000 BTU/hour on propane).
INSTALLATION REQUIREMENTS
Installation and service must be performed by a licensed contractor. The installation must conform to written Instalation & Operating Instructions and local codes. In the absence of local codes, the installation must conform with the National Fuel Gas code, ANSI Z223.1 (latest edition also known as NFPA54) or GCA B149 (latest edition) installation codes. These codes are available from the National Fire Protection Association, Inc., Batterymarch Park, Quincy, MA 02269 or the Canadian Gas Association, 55 Scarsdale Road, Toronto, Ontario M3B 2R3, CANADA.
FOR YOUR SAFETY
Operate infrared heaters with proper care and observe all safety precautions. Carefully follow printed installation, operating and cleaning instructions furnished with the heater. Do not store gasoline or combustible products in the vicinity of the heater. Do not touch the heater or the tubes while the heater is in operation. Adequate ventilation must always be provided in accordance with codes.
Parabolic Reflector Extension
The Parabolic Reflector Extension is used to increase the intensity of the heater by focusing inrared energy in a narrower area for spot heating applications. Details on Parabolic Reflector Extension Kit (PDF)
Troubleshooting
Troubleshooting Flowcharts are located toward the end of each products I & O pdf.